FL2X Copper Conductor Automotive cables
FL2X Copper Conductor Automotive cables
Application:
This PVC-insulated single-core cable is for low-voltage wiring in vehicles.
Cable Construction:
Conductor: Cu-ETP1 bare according to DIN EN 13602
Insulation:XLPE
Standard: ISO 6722 Class C
Technical Parameters:
Operating temperature: –40°C to +125°C
| Conductor Construction | Insulation | Cable | |||||
| Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20℃ max. | Nominal thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. | 
| mm2 | No./mm | mm | mΩ/m | mm | mm | mm | kg/km | 
| 1×0.50 | 16/0.21 | 1.1 | 37.1 | 0.6 | 2.1 | 2.3 | 8 | 
| 1×0.75 | 24/0.21 | 1.3 | 24.7 | 0.6 | 2.35 | 2.5 | 11 | 
| 1×1.00 | 32/0.21 | 1.5 | 18.5 | 0.6 | 2.55 | 2.7 | 14 | 
| 1×1.50 | 30/0.26 | 1.8 | 12.7 | 0.6 | 2.85 | 3 | 19 | 
| 1×2.00 | 40/0.26 | 2 | 9.42 | 0.6 | 3.15 | 3.3 | 24 | 
| 1×2.50 | 50/0.26 | 2.2 | 7.6 | 0.7 | 3.45 | 3.6 | 30 | 
| 1×3.00 | 60/0.26 | 2.4 | 6.15 | 0.7 | 3.95 | 4.1 | 38 | 
| 1×4.00 | 56/0.31 | 2.8 | 4.71 | 0.8 | 4.2 | 4.4 | 48 | 
| 1×6.00 | 84/0.31 | 3.4 | 3.14 | 0.8 | 4.8 | 5 | 68 | 